Medical Infant Radiant Warmer with Phototherapy Radiant box
Brief Introduction
Three control Modes: Pre- warm Mode, Manual Mode and Baby Mode control by micro-computer;
Set Temperature and skin temperature can be displayed separately;
Main body is made of stainless steel;
Double sides phototherapy radiant box;
Acrylic glass bassinet;
APGAR timer;
Multiple failure alarm indications;
RS232 connector for data output;
Disposable skin temperature sensor and SpO2 are optional.
Standard Configuration:
Warmer module, temperature controller, bassinet, phototherapy radiant box, and the stand.
Medical Infant Radiant Warmer with Phototherapy Radiant box Specification:
Environmental Requirement:
Operating range: 18°C-30°C
Ambient air velocity rate: <0.3m/s
Medical Infant Radiant Warmer with Phototherapy Radiant box Product Packaging:
Package: The whole unit is packed into one carton
Dimension: 940mmx 570mm x 1080mm
Gross Weight: 57 Kg
Medical Infant Radiant Warmer with Phototherapy Radiant box Picture:
Brief Introduction
Three control Modes: Pre- warm Mode, Manual Mode and Baby Mode control by micro-computer;
Set Temperature and skin temperature can be displayed separately;
Main body is made of stainless steel;
Double sides phototherapy radiant box;
Acrylic glass bassinet;
APGAR timer;
Multiple failure alarm indications;
RS232 connector for data output;
Disposable skin temperature sensor and SpO2 are optional.
Standard Configuration:
Warmer module, temperature controller, bassinet, phototherapy radiant box, and the stand.
Medical Infant Radiant Warmer with Phototherapy Radiant box Specification:
Power input requirement | AC220V-230V/50Hz or AC110V-120V/50-60Hz, 850VA |
Control Mode | Pre-warm mode, manual mode and baby mode are controlled by micro-computer |
Baby mode temperature control range | 34.5°C-37.5°C |
Skin temperature display range | 5°C-65°C |
Accuracy of skin temperature sensor | ±0.2°C |
Temperature uniformity of mattress | ≤2°C |
Dominant wavelength of blue light | 420- 470nm |
Timing range of blue light | 0~9999hrs 59min |
APGAR timer | audible and visible alarm when the device runs to50" ~1' ,4' 50"~5' ,9' 50"~10' |
Failure alarm | Over Temperature Alarm, Deviation Alarm, Sensor Failure Alarm, Power Failure Alarm, Setting Alarm, Checking Alarm and so on. |
Average value of general bilirubin radiation on the mattress effective range | ≥250uW/cm2 (the upper phototherapy equipment) ≥600uW/cm2 (the nether phototherapy equipment) |
Bilirubin uniformity of radiating on the mattress effective range | >0.4 |
Environmental Requirement:
Operating range: 18°C-30°C
Ambient air velocity rate: <0.3m/s
Medical Infant Radiant Warmer with Phototherapy Radiant box Product Packaging:
Package: The whole unit is packed into one carton
Dimension: 940mmx 570mm x 1080mm
Gross Weight: 57 Kg
Medical Infant Radiant Warmer with Phototherapy Radiant box Picture: